广州鸿懿电气设备有限公司 |
产品 规格:【德国原装,全新*】
产品 质量:【*,假一罚十】
产品 价格:【薄利多销,行业zui低】
产品 货期:【库存销售,现买现卖】
:*
;
:
广州鸿懿电气设备有限公司竭诚为您服务
更多产品和报价咨询扫二维码加我
购物需知
1 、西门子 产品均为密封包装,外包装详见产品图片,白色标签上均有西门子品牌 LOGO 及产品订货号,各位买家在收到货后,请核对型号无误,再拆包装
2、本公司销售的产品一律为(原装* * 假一罚十 * 质保一年) 本公司签约正式的销售合同,开具 17% 的增值税发票、普通发票。
万喜堂app下载网页版 6SL3210-1KE11-8UB2
西门子产品订货号:6SL32101KE118UB2
西门子产品价格:168 RMB
西门子产品净重: 1.100 Kg
西门子产品承诺:质保一年,原装*
西门子产品尺寸: 270.00 x 225.00 x 85.00
SINAMICS G120C, frame sizes FSAA to FSF, with Inligent Operator Panel IOP
SINAMICS G120C compact inverters offer a well-balanced combination of features to address a wide range of applications. They are compact, rugged devices that are easy to operate and can be optionally equipped with a basic or advanced operator panel.
SINAMICS G120C inverters are especially suitable when it comes to meeting the requirements of system integrators, OEMs and distributors regarding high productivity and tailored performance.
SINAMICS G120C is a compact converter for control cabinet mounting in IP20 degree of protection where the Control Unit (CU) and Power Module (PM) function units are combined in one device.
The compact mechanical design and the high power density allow these devices to be installed in machine control enclosures and control cabinets for maximum space utilization. The SINAMICS G120C compact converter can be butt-mounted directly, without derating at temperatures up to 40 °C (104 °F).
SINAMICS G120C, frame size FSAA with BOP-2
SINAMICS G120C can be integrated into the widest range of applications, either using the integrated digital and analog inputs or via the integrated fieldbus interface (available in USS, Modbus RTU, PROFIBUS, PROFINET / EtherNet/IP versions). Especially the product versions with integrated PROFIBUS/PROFINET interface make full integration into the Siemens TIA family possible, therefore allowing the advantages of the seamless TIA product family to be fully utilized. SINAMICS G120C devices are preset in the factory so that they can be immediay connected to PROFIBUS and/or PROFINET fieldbus systems without parameterization.
SINAMICS G120C is also equipped with the safety function STO (Safe Torque Off) as standard, which is used to safely stop drives. As a consequence, machine manufacturers can simply comply with current machinery directives with minimum associated costs.
SINAMICS G120C can control asynchronous (induction) motors in the power range from 0.37 kW up to 132 kW (0.5 hp to 200 hp). Reliable and efficient motor operation is achieved by using state-of-the-art IGBT technology combined with vector control. The extensive range of functions integrated in the SINAMICS G120C also offers a high degree of protection for the converter and motor.
Line-side components
Line reactors
Line reactors smooth the current drawn by the converter and thus reduce harmonic components in the line current. Through the reduction of the current harmonics, the thermal load on the power components in the rectifier and in the DC-link capacitors is reduced as well as the harmonic effects on the supply. The use of a line reactor increases the service life of the converter.
Recommended line-side power components
Standard fuses can be used for the SINAMICS G120C. These must be dimensioned to comply with local regulations. In this chapter, you will find recommended components such as fuses and circuit breakers in compliance with IEC and UL regulations.
DC link components
Braking resistors
Excess energy in the DC link is dissipated in the braking resistor. The braking resistors are designed for use with the SINAMICS G120C. This has an integrated braking chopper (electronic switch).
Load-side power components
Output reactors
Output reactors reduce the rate of voltage rise (dv/dt) and the height of the current peaks, and enable longer motor cables to be connected.
Supplementary system components
Inligent Operator Panel IOP
Graphics-based, user-friendly and powerful operator panel for commissioning and diagnostics as well as local operator control and monitoring of SINAMICS G120C.
Basic Operator Panel BOP-2
A 2-line display to provide support when commissioning and troubleshooting the drive. The drive can be locally controlled.
Memory card
The parameter settings for an inverter can be stored on the SINAMICS SD memory card. When service is required, e.g. after the inverter has been replaced and the data have been downloaded from the memory card the drive system is immediay ready for use again. The associated memory card holder is integrated in the inverter.
PC inverter connection kit 2
For controlling and commissioning an inverter directly from a PC if the STARTER commissioning tool or SINAMICS Startdrive has been installed on the PC.
Spare parts
Shield plates
A set of shield plates is included in the scope of delivery for the motor and signal cables corresponding to the frame size of the SINAMICS G120C, and can also be ordered as spare parts.
Spare parts kit
This kit comprises four I/O terminals, one RS485 terminal, two pairs of Control Unit doors (1 × PN and 1 × other communication versions) and one blanking cover.
Set of connectors
A set of connectors for the line feeder cable, braking resistor and motor cable can be ordered corresponding to the frame size of the SINAMICS G120C inverter.
Roof-mounted fan
A roof-mounted fan (at the top of the device) comprising a pre-assembled unit with holder and fan can be ordered corresponding to the frame size of the SINAMICS G120C.
Fan unit
A replacement fan (at the rear of the device; heat sink) comprising a pre-assembled unit with holder and fan can be ordered corresponding to the frame size of the SINAMICS G120C.
Connection example for SINAMICS G120C
USS/Modbus RTU communication interface
PROFIBUS DP communication interface
PROFINET, EtherNet/IP communication interface
万喜堂app下载网页版 6SL3210-1KE11-8UB2
西门子产品订货号:6SL32101KE118UB2
西门子产品价格:168 RMB
西门子产品净重: 1.100 Kg
西门子产品承诺:质保一年,原装*
西门子产品尺寸: 270.00 x 225.00 x 85.00
Control Units | Power Modules degree of protection IP20 | |
---|---|---|
PM240‑2/PM240 | PM250 | |
CU230P‑2 | ✓ | ✓ |
CU240E‑2 | ✓ | ✓ |
CU250S‑2 | ✓ | ✓ |
PM240, PM240‑2 and PM250 Power Modules
Rated power 1) | Rated output current I rated 2) | PM240‑2 Power Modules 3) All CUs pluggable | PM250 All CUs pluggable | |
---|---|---|---|---|
kW | hp | A | Article No. | Article No. |
200 ... 240 V 1 AC/3 AC | ||||
0.55 | 0.75 | 3.2 | 6SL3210-1PB13-0❒L0 | – |
0.75 | 1 | 4.2 | 6SL321❒-1PB13-8❒L0 | – |
1.1 | 1.5 | 6 | 6SL3210-1PB15-5❒L0 | – |
1.5 | 2 | 7.4 | 6SL3210-1PB17-4❒L0 | – |
2.2 | 3 | 10.4 | 6SL321❒-1PB21-0❒L0 | – |
3 | 4 | 13.6 | 6SL3210-1PB21-4❒L0 | – |
4 | 5 | 17.5 | 6SL321❒-1PB21-8❒L0 | – |
200 ... 240 V 3 AC | ||||
5.5 | 7.5 | 22 | 6SL3210-1PC22-2❒L0 | – |
7.5 | 10 | 28 | 6SL3210-1PC22-8❒L0 | – |
11 | 15 | 42 | 6SL3210-1PC24-2UL0 | – |
15 | 20 | 54 | 6SL3210-1PC25-4UL0 | – |
18.5 | 25 | 68 | 6SL3210-1PC26-8UL0 | – |
22 | 30 | 80 | 6SL3210-1*-0UL0 | – |
30 | 40 | 104 | 6SL3210-1PC31-1UL0 | – |
37 | 50 | 130 | 6SL3210-1PC31-3UL0 | – |
45 | 60 | 154 | 6SL3210-1PC31-6UL0 | – |
55 | 75 | 178 | 6SL3210-1PC31-8UL0 | – |
380 ... 480 V 3 AC | ||||
0.37 4) | 0.5 | 1.3 | – 4) | – |
0.55 | 0.75 | 1.7 | 6SL3210-1PE11-8❒L1 | – |
0.75 | 1 | 2.2 | 6SL3210-1PE12-3❒L1 | – |
1.1 | 1.5 | 3.1 | 6SL3210-1PE13-2❒L1 | – |
1.5 | 2 | 4.1 | 6SL3210-1PE14-3❒L1 | – |
2.2 | 3 | 5.9 | 6SL3210-1PE16-1❒L1 | – |
3 | 4 | 7.7 | 6SL321❒-1PE18-0❒L1 | – |
4 | 5 | 10.2 | 6SL3210-1PE21-1❒L0 | – |
5.5 | 7.5 | 13.2 | 6SL3210-1PE21-4❒L0 | – |
7.5 | 10 | 18 | 6SL321❒-1PE21-8❒L0 | 6SL3225-0BE25-5AA1 |
11 | 15 | 26/25 | 6SL3210-1PE22-7❒L0 | 6SL3225-0BE27-5AA1 |
15 | 20 | 32 | 6SL321❒-1PE23-3❒L0 | 6SL3225-0BE31-1AA1 |
18.5 | 25 | 38 | 6SL3210-1PE23-8❒L0 | 6SL3225-0BE31-5❒A0 |
22 | 30 | 45 | 6SL3210-1PE24-5❒L0 | 6SL3225-0BE31-8❒A0 |
30 | 40 | 60 | 6SL3210-1PE26-0❒L0 | 6SL3225-0BE32-2❒A0 |
37 | 50 | 75 | 6SL3210-1PE27-5❒L0 | 6SL3225-0BE33-0❒A0 |
45 | 60 | 90 | 6SL3210-1PE28-8❒L0 | 6SL3225-0BE33-7❒A0 |
55 | 75 | 110 | 6SL3210-1PE31-1❒L0 | 6SL3225-0BE34-5❒A0 |
75 | 100 | 145 | 6SL3210-1PE31-5❒L0 | 6SL3225-0BE35-5❒A0 |
90 | 125 | 178 | 6SL3210-1PE31-8❒L0 | 6SL3225-0BE37-5❒A0 |
110 | 150 | 205 | 6SL3210-1PE32-1❒L0 | – |
132 | 200 | 250 | 6SL3210-1PE32-5❒L0 | – |
160 3) | 250 | 302 | 6SL3224-0XE41-3UA0 | – |
200 3) | 300 | 370 | 6SL3224-0XE41-6UA0 | – |
250 3) | 400 | 477 | 6SL3224-0XE42-0UA0 | – |
500 ... 690 V 3 AC | ||||
11 | 10 | 14 | 6SL3210-1PH21-4❒L0 | – |
15 | 15 | 19 | 6SL3210-1PH22-0❒L0 | – |
18.5 | 20 | 23 | 6SL3210-1PH22-3❒L0 | – |
22 | 25 | 27 | 6SL3210-1PH22-7❒L0 | – |
30 | 30 | 35 | 6SL3210-1PH23-5❒L0 | – |
37 | 40 | 42 | 6SL3210-1PH24-2❒L0 | – |
45 | 50 | 52 | 6SL3210-1PH25-2❒L0 | – |
55 | 60 | 62 | 6SL3210-1PH26-2❒L0 | – |
75 | 75 | 80 | 6SL3210-1PH28-0❒L0 | – |
90 | 100 | 100 | 6SL3210-1PH31-0❒L0 | – |
110 | 100 | 115 | 6SL3210-1PH31-2❒L0 | – |
132 | 125 | 142 | 6SL3210-1PH31-4❒L0 | – |
Heat sink variant | ↑ | |||
Standard | 0 | |||
Push Through | 1 | |||
Integrated line filter | ↑ | ↑ | ||
Without | (for IT systems) | U | U | |
Class A | (for TN systems) | A | A | |
Class B | (for TN systems) | – | Integrated line filter not available, as external option only |
西门子产品订货号:6SL32101KE118UB2
西门子产品价格:168 RMB
西门子产品净重: 1.100 Kg
西门子产品承诺:质保一年,原装*
西门子产品尺寸: 270.00 x 225.00 x 85.00
CPU的存储区由装载存储器、工作存储器和系统存储器组成。工作存储器类似于计算机的内存条,装载存储器类似于计算机的硬盘。
(1)装载存储器
CPU的装载存储器用于保存不包含符号地址和注释的逻辑块、数据块和系统数据(硬件组态、连接和模块的参数等)。下载程序时,用户程序(逻辑块和数据块)被下载到装载存储器,符号表和注释保存在编程设备中。在PLC上电时,CPU把装载存储器中的可执行部分复制到工作存储器,符号表和注释保存在编程设备中。在CPU断电时,需要保存的数据被自动保存在装载存储器中。
S7 - 300用MMC作装载存储器。现在生产的S7 -300 CPU没有集成的装载存储器,必须插入MMC,才能下载和运行用户程序。CPU与MMC是分开订货的。
S7 - 400的CPU有集成的装载存储器(带后备电池的RAM),也可以用FEPROM存储卡或RAM存储卡来扩展装载存储器(见图2-6)。
图2-6 存储区分布
(2)工作存储器
工作存储器是集成在CPU中的高速存取的RAM存储器,用于存储CPU运行时的用户程序和数据,例如组织块、功能块、功能和数据块。为了保证程序执行的快速性和不过多地占用工作存储器,只有与程序执行有关的块被装入工作存储器。用模式选择开关复位CPU的存储器时,RAM中的程序被清除,FEPROM中的程序不会被清除。
(3)系统存储器
系统存储器是CPU为用户程序提供的存储器组件,用于存放用户程序的操作数据,例如过程映像输入、过程映像输出、位存储器、定时器和计数器、块堆栈、中断堆栈和诊断缓冲区等。系统存储器还包括临时存储器(局部数据堆栈),在逻辑块被调用时用来储存临时变量。在执行逻辑块时它的临时变量才有效,执行完后可能被覆盖。