The sensor enabling primary element corrosion inspection, available as compact or remote device version. For steam applications with high chloride content (SAGD) aligned with ERCB.
Sensor features
Compliance to ERCB – enables customer to fullfil inspection requirements. High availability – proven robustness, resistance to vibrations, temperature shocks & water hammer. High process safety – resistant to IGSCC. Material for low medium temperatures. Inspection ports.
Nominal diameter range
DN 50 to 150 (2 to 6")
Measuring range
Liquid: 0.99 to 545 m³/h (0.58 to 321 ft³/min) depending on medium: water with 1 bar a, 20 °C (14.5 psi a, 68° F) Steam, gas: 13.8 to 7262 m³/h (8.12 to 4274 ft³/min) depending on medium: steam with 180 °C, 10 bar a (356 °F, 145 psi a); air with 25 °C, 4.4 bar a (77 °F, 63.8 psi a)
4‐20 mA HART (passive) 4‐20 mA (passive) Pulse/frequency/switch output (passive)
Inputs
4‐20 mA (passive)
Hazardous area approvals
cCSAus
Degree of protection
Compact version: IP66/67, type 4X enclosure Sensor remote version: IP66/67, type 4X enclosure Transmitter remote version: IP66/67, type 4X enclosure
Display/Operation
4‐line backlit display with touch control (operation from outside) Configuration via local display and operating tools possible Remote display available